Only some libcontainer packages can be built on non-linux platforms
(not that it make sense, but at least go build succeeds). Let's call
these "good" packages.
For all other packages (i.e. ones that fail to build with GOOS other
than linux), it does not make sense to have linux build tag (as they
are broken already, and thus are not and can not be used on anything
other than Linux).
Remove linux build tag for all non-"good" packages.
This was mostly done by the following script, with just a few manual
fixes on top.
function list_good_pkgs() {
for pkg in $(find . -type d -print); do
GOOS=freebsd go build $pkg 2>/dev/null \
&& GOOS=solaris go build $pkg 2>/dev/null \
&& echo $pkg
done | sed -e 's|^./||' | tr '\n' '|' | sed -e 's/|$//'
}
function remove_tag() {
sed -i -e '\|^// +build linux$|d' $1
go fmt $1
}
SKIP="^("$(list_good_pkgs)")"
for f in $(git ls-files . | grep .go$); do
if echo $f | grep -qE "$SKIP"; then
echo skip $f
continue
fi
echo proc $f
remove_tag $f
done
Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>
Noticed that the check of trying to use both rootful and rootless
in NewDbusConnManager never worked, as we never set dbusInited to true.
Do that. While at it, protect this with the mutex (against the
case of two goroutines simultaneously calling NewDbusConnManager).
This is a rare call, so taking read-only then read-write mutex does not
make sense.
Fixes: c7f847ed3a
Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>
gofumpt (mvdan.cc/gofumpt) is a fork of gofmt with stricter rules.
Brought to you by
git ls-files \*.go | grep -v ^vendor/ | xargs gofumpt -s -w
Looking at the diff, all these changes make sense.
Also, replace gofmt with gofumpt in golangci.yml.
Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>
Using per cgroup manager dbus connection instances means
that every cgroup manager instance gets a new connection,
and those connections are never closed, ultimately resulting
in file descriptors limit being hit.
Revert back to using a single global dbus connection for everything,
without changing the callers.
NOTE that it is assumed a runtime can't use both root and rootless
dbus at the same time. If this happens, we panic.
Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>
Instead of reconnecting to dbus after some failed operations, and
returning an error (so a caller has to retry), reconnect AND retry
in place for all such operations.
This should fix issues caused by a stale dbus connection after e.g.
a dbus daemon restart.
Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>
[@kolyshkin: doc nits, use dbus.ErrClosed and isDbusError]
Signed-off-by: Shiming Zhang <wzshiming@foxmail.com>
Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>