Do not convert blkio weight value using blkio->io conversion scheme
bfq weight controller (i.e. io.bfq.weight if present) is still using the same bfq weight scheme (i.e 1->1000, see [1].) Unfortunately the documentation for this was wrong, and only fixed recently [2]. Therefore, if we map blkio weight to io.bfq.weight, there's no need to do any conversion. Otherwise, we will try to write invalid value which results in error such as: ``` time="2021-02-03T14:55:30Z" level=error msg="container_linux.go:367: starting container process caused: process_linux.go:495: container init caused: process_linux.go:458: setting cgroup config for procHooks process caused: failed to write \"7475\": write /sys/fs/cgroup/runc-cgroups-integration-test/test-cgroup/io.bfq.weight: numerical result out of range" ``` [1] https://github.com/torvalds/linux/blob/master/Documentation/block/bfq-iosched.rst [2] https://github.com/torvalds/linux/commit/65752aef0a407e1ef17ec78a7fc31ba4e0b360f9 Signed-off-by: Daniel Dao <dqminh89@gmail.com>
This commit is contained in:
committed by
Kir Kolyshkin
parent
f245b8c207
commit
c3ffd2ef81
@@ -29,7 +29,7 @@ func setIo(dirPath string, cgroup *configs.Cgroup) error {
|
||||
if cgroup.Resources.BlkioWeight != 0 {
|
||||
filename := "io.bfq.weight"
|
||||
if err := fscommon.WriteFile(dirPath, filename,
|
||||
strconv.FormatUint(cgroups.ConvertBlkIOToCgroupV2Value(cgroup.Resources.BlkioWeight), 10)); err != nil {
|
||||
strconv.FormatUint(uint64(cgroup.Resources.BlkioWeight), 10)); err != nil {
|
||||
return err
|
||||
}
|
||||
}
|
||||
|
||||
@@ -400,17 +400,6 @@ func WriteCgroupProc(dir string, pid int) error {
|
||||
return err
|
||||
}
|
||||
|
||||
// Since the OCI spec is designed for cgroup v1, in some cases
|
||||
// there is need to convert from the cgroup v1 configuration to cgroup v2
|
||||
// the formula for BlkIOWeight is y = (1 + (x - 10) * 9999 / 990)
|
||||
// convert linearly from [10-1000] to [1-10000]
|
||||
func ConvertBlkIOToCgroupV2Value(blkIoWeight uint16) uint64 {
|
||||
if blkIoWeight == 0 {
|
||||
return 0
|
||||
}
|
||||
return uint64(1 + (uint64(blkIoWeight)-10)*9999/990)
|
||||
}
|
||||
|
||||
// Since the OCI spec is designed for cgroup v1, in some cases
|
||||
// there is need to convert from the cgroup v1 configuration to cgroup v2
|
||||
// the formula for cpuShares is y = (1 + ((x - 2) * 9999) / 262142)
|
||||
|
||||
@@ -548,20 +548,6 @@ func TestGetHugePageSizeImpl(t *testing.T) {
|
||||
}
|
||||
}
|
||||
|
||||
func TestConvertBlkIOToCgroupV2Value(t *testing.T) {
|
||||
cases := map[uint16]uint64{
|
||||
0: 0,
|
||||
10: 1,
|
||||
1000: 10000,
|
||||
}
|
||||
for i, expected := range cases {
|
||||
got := ConvertBlkIOToCgroupV2Value(i)
|
||||
if got != expected {
|
||||
t.Errorf("expected ConvertBlkIOToCgroupV2Value(%d) to be %d, got %d", i, expected, got)
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
func TestConvertCPUSharesToCgroupV2Value(t *testing.T) {
|
||||
cases := map[uint64]uint64{
|
||||
0: 0,
|
||||
|
||||
@@ -190,6 +190,20 @@ function setup() {
|
||||
[[ "$output" == *'invalid configuration'* ]]
|
||||
}
|
||||
|
||||
@test "runc run (blkio weight)" {
|
||||
requires root cgroups_v2
|
||||
|
||||
set_cgroups_path "$BUSYBOX_BUNDLE"
|
||||
update_config '.linux.resources.blockIO |= {"weight": 750}' "${BUSYBOX_BUNDLE}"
|
||||
|
||||
runc run -d --console-socket "$CONSOLE_SOCKET" test_cgroups_unified
|
||||
[ "$status" -eq 0 ]
|
||||
|
||||
runc exec test_cgroups_unified sh -c 'cat /sys/fs/cgroup/io.bfq.weight'
|
||||
[ "$status" -eq 0 ]
|
||||
[ "$output" = 'default 750' ]
|
||||
}
|
||||
|
||||